Combustion Processes

When measuring combustion gas temperatures, flames or the temperature in the firing bed, radiation thermometers offer great advantages over thermocouples:

    • Easy to access and to maintain
    • no influence of radiation from the grate
    • Fast response time
    • No aging effects

HEITRONICS offers standard solutions for use in waste incineration plants and fossil-fuel-fired power plants, which have proven themselves in several hundred installations worldwide. To this end, we also cooperate with industrial partners in the fields of plant construction, fire performance optimization and denitrification.

An extensive range of mounting and protection hardware, as well as the associated software, round off the portfolio and offer a solution for almost every measurement task. And if the solution does not yet exist, we will find it.

Applications / Processes Model Temperature Range Image
Incinerators:
• Monitoring according to
17. BlmSchV in Germany
• Fire performance control
• Combustion chamber temperature

KT19.69 II
KT15.69 II

400 … 1700 °C
Material on moving grate

KT19.41 II with special optics

250 … 1400 °C
Gas temperature distribution in the combustion chamber: SNCR Control

System consisting of:
TempControl 2.0
• Industrial computer
6x KT19.69 II

Coal fired power boiler
Fluidized bed furnace

CT18.03
KT18 RD

450 … 2000 °C
600 … 2000 °C
Cement production /
exhaust gas temperature measurement

KT18.03 RDLL
with protected fiber cable and optimized air purge fitting

600 … 1600 °C
Special solutions for
• Hazardous waste incinerator
• Chemical reactor
• Etc.

On request

WOULD YOU LIKE TO KNOW MORE?