When measuring combustion gas temperatures, flames or the temperature in the firing bed, radiation thermometers offer great advantages over thermocouples:
HEITRONICS offers standard solutions for use in waste incineration plants and fossil-fuel-fired power plants, which have proven themselves in several hundred installations worldwide. To this end, we also cooperate with industrial partners in the fields of plant construction, fire performance optimization and denitrification.
An extensive range of mounting and protection hardware, as well as the associated software, round off the portfolio and offer a solution for almost every measurement task. And if the solution does not yet exist, we will find it.
Applications / Processes | Model | Temperature Range | Image |
---|---|---|---|
Incinerators: • Monitoring according to 17. BlmSchV in Germany • Fire performance control • Combustion chamber temperature |
400 … 1700 °C | ||
Material on moving grate | KT19.41 II with special optics |
250 … 1400 °C | |
Gas temperature distribution in the combustion chamber: SNCR Control | System consisting of: |
||
Coal fired power boiler Fluidized bed furnace |
450 … 2000 °C 600 … 2000 °C |
||
Cement production / exhaust gas temperature measurement |
KT18.03 RDLL |
600 … 1600 °C | |
Special solutions for • Hazardous waste incinerator • Chemical reactor • Etc. |
On request |